设施与楼宇自控运维
Facility & building automation operations
Adjust building-automation schedules and setpoints and manage facility work orders.
20 条本项目编写的提案 · 分类 v1.1 · 新增基准运行 0 次。下方验证方式与部分得分规则是设计,不是执行结果。
- 典型应用
- Niagara · Metasys · CMMS
- 小类 GUI 需求标签
HY· 混合
任务提案 · 20
展开查看完整原文与建议检查方式;两种界面均保留提案英文原文。
R05.13.01.07-T01 Set a holiday schedule to unoccupied for four air handlers
原始指令
A Niagara 4 training station (web UI, simulated BACnet AHUs) is open. Add a holiday exception so AHU-1..AHU-4 run unoccupied from 2026-12-24 00:00 through 2026-12-26 23:59, using the existing 'Holidays' calendar referenced by each AHU's weekly schedule. Do not change the weekly schedules.
- 平台
web· 任意系统(网页)- 应用
- Niagara 4
- 交互表面
brow· 浏览器hmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击type· 文字与表单nav· 平移 / 缩放 / 滚动- 工作产物
WP08· 应用 / 系统状态- 条件
- 未声明
- 提案难度
- 2 / 5
建议验证方式
Station read via grader-only fox/BACnet: calendar has the 3-day exception; simulated occupancy for each AHU is unoccupied at sampled times in the range and occupied per weekly schedule on 12-23; weekly schedules byte-identical. Agent account lacks oBIX/BQL web access and admin/program rights, and its VM has no Workbench or fox/BACnet route to the station, so changes go through the web UI.
建议部分得分
50% exception dates; 30% effective on all 4 AHUs; 20% weekly schedules untouched.
R05.13.01.07-T02 Apply a timed cooling setpoint reduction to one floor
原始指令
In the Metasys training site (web UI), lower the occupied cooling setpoint of all 14 VAV zones on Floor 3 by 1 degF from 13:00 to 17:00 today only, using a temporary override/scheduled command that releases automatically. Other floors and other days must be unaffected.
- 平台
web· 任意系统(网页)- 应用
- Metasys
- 交互表面
brow· 浏览器hmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击type· 文字与表单nav· 平移 / 缩放 / 滚动- 工作产物
WP08· 应用 / 系统状态- 条件
- 未声明
- 提案难度
- 3 / 5
建议验证方式
Simulator log: Floor 3 zone setpoints = base - 1 between 13:00 and 17:00 sim time and back to base after; priority array released; no change elsewhere. Write access exists only through the UI session.
建议部分得分
35% all 14 zones adjusted; 35% time window and auto-release; 30% no collateral setpoint changes.
R05.13.01.07-T03 Acknowledge priority alarms and raise CMMS work orders
原始指令
The Niagara training station alarm console shows 9 unacknowledged alarms. Acknowledge the 3 with priority <= 50, and for each create a corrective work order in the CMMS (UpKeep sandbox) with asset, problem text from the alarm, priority High, and the alarm timestamp in the description. Leave lower-priority alarms unacknowledged.
- 平台
web· 任意系统(网页)- 应用
- Niagara 4 · UpKeep
- 交互表面
brow· 浏览器hmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击type· 文字与表单multi· 跨应用- 工作产物
WP08· 应用 / 系统状态- 条件
multiapp· 多应用- 提案难度
- 3 / 5
建议验证方式
Alarm DB: exactly the 3 high-priority alarms acknowledged by agent user; CMMS: 3 work orders with correct assets, priority and timestamps; low-priority alarms untouched. Station fox/BACnet access and UpKeep API tokens are withheld from the agent, so alarms must be acked in the web console and orders made in UpKeep's web app.
建议部分得分
35% correct alarms acknowledged; 45% work orders complete; 20% others untouched.
R05.13.01.07-T04 Export a supply-air trend and quantify setpoint deviation
原始指令
In the Metasys training site, export the trend of AHU-2 supply air temperature and its setpoint for 2026-10-05..11 at 5-minute samples to output/ahu2_sat.csv, then compute the percentage of occupied-hours samples where |SAT - setpoint| > 1 degF and write it to output/deviation.txt.
- 平台
web· 任意系统(网页)win· Windowsmac· macOS- 应用
- Metasys · Excel
- 交互表面
brow· 浏览器desk· 桌面 GUI- GUI 需求 · 任务设定
HY· 混合- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击nav· 平移 / 缩放 / 滚动multi· 跨应用- 工作产物
WP12· 答案 / 决策- 条件
- 未声明
- 提案难度
- 3 / 5
建议验证方式
CSV covers the range and interval with both series; percentage within 0.5 points of key computed from the simulator's history and the occupancy schedule.
建议部分得分
40% trend export; 20% occupied-hours filter; 40% percentage within tolerance.
R05.13.01.07-T05 Build a graphic page for a new air handler
原始指令
In Niagara Workbench on Windows (training station), create a Px view for AHU-5 from template sketch input/ahu5_graphic.png: duct background, animated supply fan bound to fan status, SAT and RAT value labels, damper position bar, and a setpoint field users can edit. Bind every widget to the correct point and set it as the AHU's default view.
- 平台
win· Windows- 应用
- Niagara Workbench
- 交互表面
desk· 桌面 GUIhmi· 设备 / HMI- GUI 需求 · 任务设定
G2· GUI 必要- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
drag· 拖放geom· 精确几何vis· 视觉判断click· 指向与点击- 工作产物
WP03· 视觉排版- 条件
licensed· 授权专业软件- 提案难度
- 4 / 5
建议验证方式
Parse Px XML: widget bindings to exact ord paths; widget positions within 20 px of the sketch layout; setpoint field writable; default view set. Render test: SSIM >= 0.8 vs reference rendering. Workbench program modules are disabled, the VM has no scripting runtime and file writes outside Workbench are logged, so the Px must be built in Workbench.
建议部分得分
45% correct bindings; 25% layout match; 15% writable setpoint; 15% default view.
R05.13.01.07-T06 Wire economizer enable logic on a wire sheet
原始指令
In Niagara Workbench (training station), on AHU-5's wire sheet add economizer enable logic: enable when OAT < RAT - 2 degF and OAT < 65 degF and supply fan proven, with a 5-minute minimum-on timer, and drive the outdoor-air damper command between minimum position 20% and the mixed-air PID output when enabled.
- 平台
win· Windows- 应用
- Niagara Workbench
- 交互表面
desk· 桌面 GUIhmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
drag· 拖放click· 指向与点击type· 文字与表单- 工作产物
WP06· 代码 / 工程- 条件
licensed· 授权专业软件- 提案难度
- 5 / 5
建议验证方式
Behavioral test in simulator over 6 scripted OAT/RAT profiles: enable state and damper command match the sequence (min-on timer honored); wire sheet contains no program objects (custom code blocked). Station has no scripting module.
建议部分得分
40% enable logic correct; 20% min-on timer; 30% damper command; 10% no custom code.
R05.13.01.07-T07 Override VAV dampers for balancing and release them
原始指令
In Siemens Desigo CC (training, Windows), the balancer needs VAV-3-01..VAV-3-06 at max airflow. Command each damper to 100% at operator priority from the floor graphic, record measured flows from input/tab_readings.csv into each point's comment, then release all overrides so control returns to automatic.
- 平台
win· Windows- 应用
- Desigo CC
- 交互表面
desk· 桌面 GUIhmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G3· 仅 GUI- 交互原语
click· 指向与点击type· 文字与表单vis· 视觉判断- 工作产物
WP08· 应用 / 系统状态- 条件
licensed· 授权专业软件risk· 高风险 / 不可逆- 提案难度
- 3 / 5
建议验证方式
Command log: 6 overrides then 6 releases by agent user; final priority arrays have no operator entries; comments with flows exact. Leaving any override in place fails that milestone. Desigo CC's web/OPC/BACnet interfaces are firewalled from the agent VM, so commands must come from the floor graphic in the client.
建议部分得分
30% overrides applied; 30% flows recorded; 40% all released.
R05.13.01.07-T08 Create a delayed high-temperature alarm with routing
原始指令
In EcoStruxure Building Operation WorkStation (training server), create an alarm on CHW supply temperature: high limit 48 degF, 10-minute time delay, 1 degF deadband, priority 'Critical', routed to notification group 'Plant Ops' with acknowledgement required. Test it with the simulator ramp in input/ramp.txt.
- 平台
win· Windows- 应用
- EcoStruxure Building Operation
- 交互表面
desk· 桌面 GUIhmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G3· 仅 GUI- 交互原语
click· 指向与点击type· 文字与表单- 工作产物
WP08· 应用 / 系统状态- 条件
licensed· 授权专业软件- 提案难度
- 3 / 5
建议验证方式
Alarm object properties exact; simulator ramp produces exactly one alarm after 10 min above 48 and return-to-normal below 47; notification delivered to group. EBO web services and Script programs are disabled for the agent account, so the alarm must be configured in WorkStation.
建议部分得分
50% alarm properties; 30% behavior under ramp; 20% routing.
R05.13.01.07-T09 Retune a hunting discharge-air PID loop
原始指令
In the Niagara training station (simulated AHU-3 with plant dynamics running in real time at 10x), the discharge-air temperature loop oscillates. Observe the trend, then adjust proportional and integral gains on the PID block until a 2 degF setpoint step settles within 15 sim-minutes with overshoot below 1 degF and no sustained oscillation.
- 平台
win· Windowsweb· 任意系统(网页)- 应用
- Niagara 4
- 交互表面
desk· 桌面 GUIhmi· 设备 / HMI- GUI 需求 · 任务设定
G2· GUI 必要- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
rt· 实时控制vis· 视觉判断type· 文字与表单- 工作产物
WP07· 仿真结果- 条件
licensed· 授权专业软件- 提案难度
- 5 / 5
建议验证方式
Grader applies a fresh setpoint step with the final gains: settling time <= 15 sim-min, overshoot < 1 degF, decay ratio < 0.25; gains within block limits. Program objects are disabled and fox/BACnet ports are firewalled from the agent, so gains must be edited on the PID block property sheet.
建议部分得分
40% settling time; 30% overshoot; 30% no sustained oscillation.
R05.13.01.07-T10 Execute a demand-response load shed and verify kW reduction
原始指令
The utility called a DR event 14:00-18:00 (sim time). In the Metasys training site, apply the shed plan in input/dr_plan.pdf: +2 degF cooling setpoint reset on non-critical zones, disable 2 of 4 corridor lighting groups, cap AHU fan speeds at 80%. Total building kW must drop >= 15% vs baseline, and everything restores at 18:00.
- 平台
web· 任意系统(网页)- 应用
- Metasys
- 交互表面
brow· 浏览器hmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击type· 文字与表单rt· 实时控制- 工作产物
WP08· 应用 / 系统状态- 条件
- 未声明
- 提案难度
- 4 / 5
建议验证方式
Simulator meter: average kW during event <= 0.85 x baseline; only non-critical zones reset; settings restored by 18:05 sim; no critical zones touched. Metasys REST API credentials are withheld and the BACnet network is firewalled from the agent VM, so commands must come from the Metasys UI.
建议部分得分
40% kW reduction met; 25% correct zones/groups; 25% restoration; 10% critical zones untouched.
R05.13.01.07-T11 Create preventive maintenance schedules for pumps
原始指令
In IBM Maximo (training), create PM records for the 8 pumps in input/pumps.xlsx: monthly lubrication job plan JP-LUBE and quarterly vibration route JP-VIB, starting next Monday 2026-10-19, frequency from last start, with the assigned crafts. Generate the first work orders.
- 平台
web· 任意系统(网页)- 应用
- IBM Maximo · Excel
- 交互表面
brow· 浏览器- GUI 需求 · 任务设定
HY· 混合- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击type· 文字与表单multi· 跨应用- 工作产物
WP08· 应用 / 系统状态- 条件
- 未声明
- 提案难度
- 3 / 5
建议验证方式
PM table: 16 PMs (8 x 2) with asset, job plan, frequency, start date and crafts; first work orders generated with target dates.
建议部分得分
50% PM records; 25% frequencies and dates; 25% work orders generated.
R05.13.01.07-T12 Close completed work orders with labor and parts
原始指令
In UpKeep (sandbox), close the 10 completed work orders listed in input/tech_notes.md: record labor hours per technician, parts used from inventory with quantities, completion notes, and set status Complete. Two notes say the job is not finished; leave those In Progress with the note added.
- 平台
web· 任意系统(网页)- 应用
- UpKeep
- 交互表面
brow· 浏览器- GUI 需求 · 任务设定
HY· 混合- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击type· 文字与表单- 工作产物
WP08· 应用 / 系统状态- 条件
- 未声明
- 提案难度
- 2 / 5
建议验证方式
Work orders: 8 complete with labor and parts lines exact (inventory decremented), 2 in progress with notes.
建议部分得分
35% labor; 35% parts; 20% statuses; 10% notes.
R05.13.01.07-T13 Find top downtime assets and open root-cause work orders
原始指令
In Fiix CMMS (sandbox), use the downtime records for Q3 2026 to find the 3 assets with the most unplanned downtime hours, then create an RCA work order for each with type 'Root Cause Analysis', the downtime total in the description, and assignment to the reliability engineer. Write the ranking to output/top3.csv.
- 平台
web· 任意系统(网页)- 应用
- Fiix
- 交互表面
brow· 浏览器- GUI 需求 · 任务设定
HY· 混合- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
nav· 平移 / 缩放 / 滚动click· 指向与点击type· 文字与表单- 工作产物
WP08· 应用 / 系统状态- 条件
- 未声明
- 提案难度
- 3 / 5
建议验证方式
CSV ranking and hours equal key; 3 RCA work orders with correct assets, type, description hours and assignee.
建议部分得分
40% ranking; 15% hours; 45% RCA work orders.
R05.13.01.07-T14 Complete a work order checklist on a phone
原始指令
On an Android emulator with the UpKeep mobile app (technician account), open work order WO-2291 'Monthly AHU-2 inspection', complete the 8-item checklist per input/inspection_results.txt, enter the filter differential-pressure meter reading, attach the photo from the gallery, and submit.
- 平台
and· Android- 应用
- UpKeep mobile
- 交互表面
mob· 移动触控- GUI 需求 · 任务设定
HY· 混合- GUI 需求 · 普通权限
G3· 仅 GUI- 交互原语
touch· 触控手势type· 文字与表单- 工作产物
WP08· 应用 / 系统状态- 条件
- 未声明
- 提案难度
- 2 / 5
建议验证方式
Work order checklist responses exact; meter reading on the right meter; photo attached; status complete; events from mobile client.
建议部分得分
50% checklist; 20% meter; 15% photo; 15% submitted.
R05.13.01.07-T15 Schedule after-hours HVAC for a tenant and bill it
原始指令
Tenant 'Suite 410' requested after-hours HVAC (input/ahhvac_request.eml) for Saturday 2026-10-17 09:00-14:00. In the Metasys training site, add a one-time occupied event for the zones serving Suite 410 only, then in the CMMS (UpKeep sandbox) create a billable request with 5 hours at the lease rate in input/lease_rates.csv.
- 平台
web· 任意系统(网页)- 应用
- Metasys · UpKeep
- 交互表面
brow· 浏览器hmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击type· 文字与表单multi· 跨应用- 工作产物
WP08· 应用 / 系统状态- 条件
multiapp· 多应用- 提案难度
- 4 / 5
建议验证方式
Simulator occupancy for the 3 Suite 410 zones on the date/time only; no other zones; CMMS request with hours and amount = 5 x rate. Metasys REST and UpKeep API credentials are withheld from the agent, so the event and request must be made in the two web UIs.
建议部分得分
50% correct zones and window; 15% no other zones; 35% billing record.
R05.13.01.07-T16 Discover BACnet devices and map tagged points
原始指令
In Niagara Workbench (training station on a simulated BACnet/IP network), discover the 3 new VAV controllers, add them to the station, and map 12 points (zone temp, setpoints, damper, airflow) using the naming convention in input/naming.md, correct engineering units, and Haystack tags (zone, air, temp, sensor, etc.).
- 平台
win· Windows- 应用
- Niagara Workbench
- 交互表面
desk· 桌面 GUIhmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击drag· 拖放type· 文字与表单- 工作产物
WP08· 应用 / 系统状态- 条件
licensed· 授权专业软件- 提案难度
- 4 / 5
建议验证方式
Station export: 3 devices with correct instance numbers; 12 proxy points bound to the right object ids; names, units and tag sets match key. Workbench program modules are disabled and the VM has no BACnet tool outside Workbench, so discovery and point mapping must be done in Workbench.
建议部分得分
25% devices; 35% point bindings; 20% names/units; 20% tags.
R05.13.01.07-T17 Control: write the T01 holiday exception over BACnet
原始指令
Control pair of T01. Using a BACnet command-line tool or Python bacpypes on the same simulated network (device and object ids in input/bacnet_map.json), write the 2026-12-24..26 date-range exception into the Calendar object referenced by AHU-1..4 schedules.
- 平台
lin· Linuxwin· Windowsmac· macOS- 应用
- bacpypes · Python
- 交互表面
term· 终端- GUI 需求 · 任务设定
CL· CLI 足够- GUI 需求 · 普通权限
AP· API 足够- 交互原语
code· 代码与命令- 工作产物
WP08· 应用 / 系统状态- 条件
- 未声明
- 提案难度
- 3 / 5
建议验证方式
Same occupancy checks as T01 via the simulator.
建议部分得分
50% exception dates; 30% effective on all AHUs; 20% weekly schedules untouched.
R05.13.01.07-T18 Detect simultaneous heating and cooling from zone trends
原始指令
In the Niagara training station, review last week's trends for the 20 VAV zones with reheat on Floor 2. Identify zones where reheat valve > 10% while the AHU supplies air below 58 degF and zone is above its cooling setpoint for > 2 h total. Create a CMMS (Fiix sandbox) work order per zone and list them in output/shc.csv.
- 平台
web· 任意系统(网页)- 应用
- Niagara 4 · Fiix
- 交互表面
brow· 浏览器hmi· 设备 / HMI- GUI 需求 · 任务设定
HY· 混合- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
vis· 视觉判断nav· 平移 / 缩放 / 滚动multi· 跨应用- 工作产物
WP12· 答案 / 决策- 条件
multiapp· 多应用- 提案难度
- 4 / 5
建议验证方式
CSV zone set equals key (5 zones) with hours within 0.25 h; work orders for those zones only.
建议部分得分
50% zone set; 20% hours; 30% work orders.
R05.13.01.07-T19 Create an astronomical lighting schedule with offsets
原始指令
In the Niagara training station lighting module, create a schedule for parking-lot lighting groups PL-1..PL-3: on at sunset +15 min, off at 23:00, back on at 05:00, off at sunrise -10 min, for the site latitude/longitude in the station, and link it to the 3 groups.
- 平台
web· 任意系统(网页)- 应用
- Niagara 4
- 交互表面
brow· 浏览器hmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击type· 文字与表单- 工作产物
WP08· 应用 / 系统状态- 条件
- 未声明
- 提案难度
- 3 / 5
建议验证方式
Simulated output for 7 sampled dates matches astronomical on/off times +/- 2 min; all 3 groups follow the schedule. Agent account lacks program rights and has no fox/BACnet access, so the schedule must be built in the web UI.
建议部分得分
40% sunset/sunrise offsets; 30% fixed times; 30% linked to groups.
R05.13.01.07-T20 Change a building over from heating to cooling season
原始指令
In the Metasys training site, execute the seasonal changeover checklist input/changeover.pdf: switch the plant mode, enable chiller staging and disable boiler lead/lag, update 40 zone setpoints via the group command, adjust AHU discharge reset schedules and occupancy schedules for summer hours, and verify in the simulator that space temps hold within setpoint +/-1.5 degF for 2 sim-hours.
- 平台
web· 任意系统(网页)- 应用
- Metasys
- 交互表面
brow· 浏览器hmi· 设备 / HMI- GUI 需求 · 任务设定
G3· 仅 GUI- GUI 需求 · 普通权限
G2· GUI 必要- 交互原语
click· 指向与点击type· 文字与表单nav· 平移 / 缩放 / 滚动rt· 实时控制- 工作产物
WP08· 应用 / 系统状态- 条件
long· 长流程- 提案难度
- 5 / 5
建议验证方式
Simulator state after 2 sim-hours: plant mode cooling, chillers staged, boilers off, 40 setpoints per checklist, reset and schedules exact; >= 95% of zone samples within +/-1.5 degF. Metasys REST API credentials are withheld and the BACnet network is firewalled from the agent VM, so commands must come from the Metasys UI.
建议部分得分
20% plant mode; 20% setpoints; 20% reset/schedules; 40% comfort verification.
已有研究映射
当前映射未给此小类指定基准参考。